Ariston Boiler Issues: Errors and Fault Codes

When your Ariston boiler develops a fault, an error code will appear on the display panel. Most error codes include three numbers, but some are a mixture of a letter and a couple of numbers. Some fault codes apply to all Ariston combi, system and regular boilers, whereas others are unique to a specific model or range. All Ariston boiler fault codes help make it easy for your heating engineer to diagnose problems and solve issues with your boiler. 

You can find fault codes for your Ariston boiler in your user manual or by referring to the tables below. 

Ariston Clas Net One Combi, E-System One and Clas System One Boiler Fault Codes

CENTRAL HEATING CIRCUIT 
DISPLAYDESCRIPTION
101Overheat
103Insufficient circulation
104Insufficient circulation
105Insufficient circulation
106Insufficient circulation
107Insufficient circulation
108Insufficient water (request filling)
109System pressure > 3 bar 
110C.H. flow temp. probe circuit open / short circuit
112C.H. return temp. probe circuit open / short circuit
114External sensor circuit open / short circuit
116Floor thermostat contact open 
118Heating delivery probe problem
1P1Insufficient circulation indication
1P2Insufficient circulation indication
1P3Insufficient circulation indication
1P4Insufficient circulation indication
D.H.W. CIRCUIT 
205DHW in probe open circuit (Solare temp. probe)
INERNAL P.C.B.’s 
301EEPROM error
302Communication error
303Main PCB error
304Too many (>5) resets in 15 minutes
305Main PCB error
306Main PCB error
307Main PCB error
3P9Sched. Maintenance – Call Service
EXTERNAL P.C.B.’s
411Room sensor circuit open or short circuit Zone 1
412Room sensor circuit open or short circuit Zone 2
413Room sensor circuit open or short circuit Zone 3
IGNITION AND DETECTION
501No flame detected        
502Flame detected with gas valve closed
504Flame lift
5P11st ignition failed
5P22nd ignition failed
5P3Flame cut-off
AIR INLET / FLUE GAS OUTLET 
610Overheat (Main heat exchanger)
612Insufficient fan speed
MULTI-ZONE HEATING (HEATING ZONE MODULES – OPTIONAL)
701Zone 1 send sensor defective
702Zone 2 send sensor defective
703Zone 3 send sensor defective
711Zone 1 return sensor defective
712Zone 2 return sensor defective
713Zone 3 return sensor defective
722Zone 2 overheating
723Zone 3 overheating
750All heating zones locked

Ariston Clas HE Evo Combi Boiler Fault Codes

CENTRAL HEATING CIRCUIT 
DISPLAYDESCRIPTION
101Overheat
102Pressure sens error
103Insufficient circulation
104Insufficient circulation
105Insufficient circulation
106Insufficient circulation
107Insufficient circulation
108Insufficient water (request filling)
110C.H. flow temp. probe circuit open / short circuit
112C.H. return temp. probe circuit open / short circuit
114External sensor circuit open / short circuit
116Floor thermostat contact open 
118Heating delivery probe problem
1P1Insufficient circulation indication
1P2Insufficient circulation indication
1P3Insufficient circulation indication
D.H.W. CIRCUIT
202Bottom storage temperature probe open / short circuit
204Solar collector temperature probe open / short circuit
207Solar collector overheating
208Collector frost protection temperature
INERNAL P.C.B.’s 
301EEPROM error
302Communication error
303Main PCB error
304Too many (>5) resets in 15 minutes
305Main PCB error
306Main PCB error
307Main PCB error
EXTERNAL P.C.B.’s 
407Room sensor circuit open / short circuit
IGNITION AND DETECTION 
501No flame detected        
502Flame detected with gas valve closed
504Flame lift
5P11st ignition failed
5P22nd ignition failed
5P3Flame cut-off
AIR INLET / FLUE GAS OUTLET
604Insufficient fan speed
610Thermofuse open
MULTI-ZONE HEATING (HEATING ZONE MODULES – OPTIONAL) 
701Zone 1 outgoing sensor defective
702Zone 2 return sensor defective
703Zone 3 outgoing sensor defective
704Zone 3 return sensor defective
705Hydraulic separation sensor defective
706Zone 2 overheating
707Zone 3 overheating

Ariston Clas HE Regular Boiler Fault Codes

CENTRAL HEATING CIRCUIT 
DISPLAYDESCRIPTION
101Overheat
102Pressure sens error
103Insufficient circulation
104Insufficient circulation
105Insufficient circulation
106Insufficient circulation
107Insufficient circulation
110Flow temp. probe circuit open / short circuit
112Return temp. probe circuit open / short circuit
114External sensor circuit open / short circuit
118Heating delivery probe problem
1P1Insufficient circulation indication
1P2Insufficient circulation indication
1P3Insufficient circulation indication
INERNAL P.C.B.’s
301EEPROM error
302Communication error
303Main PCB error
304Too many (>5) resets in 15 minutes
305Main PCB error
306Main PCB error
307Main PCB error
IGNITION AND DETECTION
501No flame detected        
502Flame detected with gas valve closed
504Flame lift
5P11st ignition failed
5P22nd ignition failed
5P3Flame cut-off
AIR INLET / FLUE GAS OUTLET 
604Insufficient fan speed
610Thermofuse open